Hammer troubleshooting
Your hydraulic hammer stopped working, or it hits weakly? Run these checks first. Most hammers that “won’t work” only need commissioning, not repair.
The 60-second checks
Six things to confirm before anything else. Tick them off as you go; you will need the answers if you contact us.
0 of 6 checked.
Find your symptom
Open the one that matches, and work through it in order. Stop as soon as the hammer runs properly.
AThe hammer will not strike
Almost always a commissioning problem on a new install: pressure, flow or nitrogen.
1 · Check pressure and flow
Measure the pressure in the hammer line, or read the carrier’s gauge, and compare with the table below. Too little pressure or flow is the most common cause.
2 · Re-commission the nitrogen
- Release the back head nitrogen down to 3–10 kg/cm² (43–142 psi), or empty it.
- Press the chisel down onto the material and test-fire.
- Once it strikes, recharge in steps of 2 kg/cm² up to 16 kg/cm² (230 psi), testing as you go.
3 · Reverse the lines briefly
- Empty the nitrogen.
- Swap the IN and OUT hoses and fire for no more than 1 minute to free a stuck valve.
- Reconnect the hoses the correct way round, test, then recharge the nitrogen.
4 · Still nothing
Dirt has probably reached the control (reversing) valve. It needs flushing or replacing by a hydraulic technician. Contact us with the details at the bottom of this page.
BThe hammer hits weakly or slowly
| Cause | How to check | Fix |
|---|---|---|
| Low nitrogen | Read the back head charge cold. | Raise it in 2 kg/cm² steps to the value in the table below. |
| Low carrier pressure | Measure at the hammer line. | Have the relief and pump pressure set by a technician. |
| Oil too hot | Read the temperature after 10 minutes. | Keep 60–80 °C. Above 90 °C stop and cool. Replace tired oil; VG 46 cold, VG 68 hot. |
| Frequency valve too tight | Models from the JMASB81EBH up have an FM adjuster. | Quarter turn at a time: clockwise slows the blow rate, counterclockwise speeds it up. |
| Not enough down-force | Watch the carrier’s front while breaking. | Press down until the front just lightens; keep the chisel at 90°. |
| Worn chisel or bush | Check the gap between chisel and front bush. | Replace the bush over 6 mm (small models) or 8 mm (large). |
COil leaks after the hammer has stood
The main oil seal was crushed by the way the hammer was stored, or it has simply aged. Expect to change the main seal every 800–1,000 hours or 3–6 months, depending on how hard the hammer works.
How to store a hammer
- Release all nitrogen from the back head, and from the accumulator on large models.
- Remove the chisel.
- Push the piston fully in with a round bar, then grease the front head well.
- Lay it flat on timber, cap the hoses, keep it under cover.
DOther faults: shaking hoses, gas loss, stuck chisel, overheating
| Symptom | Likely cause | Fix |
|---|---|---|
| Hoses shake violently | Low nitrogen in the back head or accumulator; damaged diaphragm. | Stop work, check and recharge. Replace the diaphragm if it will not hold. |
| Irregular blows | Too little down-force, hot oil, high back pressure, worn chisel or bush. | Fix the technique first, then check cooler, filter and bush wear. |
| Gas will not hold | Damaged charging-valve O-ring, back head O-ring or gas seal. | Replace the O-rings from the seal kit; test with soapy water. |
| Chisel sticks or breaks | No grease, angled blows, prying, worn bush, blank firing. | Grease every 2 hours, keep the chisel square, never pry, replace the bush. |
| Hammer overheats | Engine speed too high, flow above range, dirty cooler. | Run at rated rpm, set the flow, clean the cooler. |
Flow, pressure and nitrogen
What the carrier must deliver at the hammer, and what the gas charge should read cold. These are the same figures shown on each product page; the last column is the ceiling the hammer must never run above.
| Model | Chisel Ø | Flow (L/min) | Flow (GPM) | Operating pressure (kg/cm²) | Operating pressure (psi) | Never exceed |
|---|---|---|---|---|---|---|
| JMASB20EBH | 45 mm | 20–30 | 5.3–7.9 | 90–120 | 1,280–1,707 | 140 |
| JMASB30EBH | 53 mm | 25–50 | 6.6–13.2 | 90–120 | 1,280–1,707 | 140 |
| JMASB40EBH | 68 mm | 40–70 | 10.6–18.5 | 110–140 | 1,565–1,991 | 160 |
| JMASB43EBH | 75 mm | 50–90 | 13.2–23.8 | 120–150 | 1,707–2,133 | 160 |
| JMASB50EBH | 100 mm | 80–110 | 21.1–29.1 | 150–170 | 2,133–2,418 | 200 |
| JMASB60EBH | 125 mm | 90–120 | 23.8–31.7 | 150–170 | 2,133–2,418 | 220 |
| JMASB81EBH | 140 mm | 120–180 | 31.7–47.6 | 160–180 | 2,276–2,560 | 240 |
| JMASB121EBH | 155 mm | 180–240 | 47.6–63.4 | 160–180 | 2,276–2,560 | 260 |
| JMASB131EBH | 165 mm | 200–260 | 52.8–68.7 | 160–180 | 2,276–2,560 | 260 |
| JMASB200EBH | 200 mm | 280–350 | 74.0–92.5 | 240–260 | 3,414–3,698 | 280 |
Back head nitrogen
JMASB20–SB50: 16–17 kg/cm², max 18
JMASB60–SB81: 17–18, max 19
JMASB121–SB200: 17–19, max 23
Standard for all models: 16.5 kg/cm² (235 psi). Adjust in 2 kg/cm² steps.
Accumulator nitrogen
Fitted on the JMASB121EBH, SB131EBH and SB200EBH. Standard 60 kg/cm² (855 psi), adjustable 55–65 as needed. It cushions the oil pressure and protects the carrier’s pump.
Still not fixed?
Send us these six things and we can usually tell you what is wrong without the hammer leaving the job.
- Model and serial number from the data plate
- Carrier make, model and operating weight
- Hours on the hammer
- Measured flow, pressure and oil temperature
- Nitrogen reading, back head and accumulator
- A short video of the hammer running